Installed by EPRA-licensed technicians only Every price dated and sourced. Last check 28 Nov 2026
Guide · Livestock

Solar water pump for livestock and dairy cows

How much water cows, goats and sheep drink, what that means in litres per day for a herd of 5, 10 or 15 cows, and how to size the pump, the tank, the trough and the float.

Updated 28 Nov 2026 · 9 min read By Peter Kamau
Farmers watering dairy cows at a trough in Kenya
On this pageHow much water do animals drink?Step 1: add up the herdStep 2: the pump depends on lift, not herd sizeBorehole, dam or river?Tank, trough and floatWhat to do next
The short answer

A dry cow needs 30 to 50 litres a day and a lactating cow 50 to 100 (a Kenyan study citing Lardy et al. 2008). High-yielding cows drink more, up to about 155 litres at 45 kg of milk a day (NDSU). The KALRO manual gives an adult goat about 2 litres. Add up your herd, then size the pump to your total lift.

If you keep cows, goats or sheep on a farm you manage from Nairobi, the water question is simple: how many litres a day, and can the pump deliver them at your depth. This guide gives the figures from Kenyan and university sources, a worked example, and the trough and float details. Use the sizing calculator for your own numbers, see solar borehole pumps, or read how borehole solarization works. All guides are on the guides page.

How much water do animals drink?

Cows. A study of smallholder dairy farms around Wote in Makueni County (Njarui and colleagues, 2014) cites Lardy et al. (2008): dry cows need 30 to 50 litres a day and lactating cows 50 to 100 litres, depending on milk production. The authors did not measure intake themselves and say that the lower and upper limits for their region still need to be determined. Treat these as the working range for Kenyan dairy cows.

Higher-yielding cows drink more. North Dakota State University Extension, using US figures, gives these ranges, converted here to litres at 3.785 litres per US gallon:

Animal Milk per day Water per day
Milking cow 13.6 kg 68 to 83 litres
Milking cow 22.7 kg 87 to 102 litres
Milking cow 36.3 kg 114 to 136 litres
Milking cow 45.4 kg 132 to 155 litres
Dry cow none 34 to 49 litres
Heifer (5 to 24 months) none 14 to 36 litres
Calf (1 to 4 months) none 5 to 13 litres

These are US animals on US feed. Most smallholder cows in Kenya give less milk, so the lower rows are the closer match. The University of Kentucky says a cow needs 4 to 4.5 pounds of water for each pound of milk, and that milk is 87% water. The UC Davis and CIMMYT fact sheet adds that free drinking water covers 80 to 90% of a lactating cow’s water, and that heat, feed moisture and milk yield change the amount.

Goats. A KALRO training manual says an adult goat should take about 2 litres of water a day. It gives no figure for lactating does or hot weather, and we found no Kenyan source that does.

Sheep. NDSU Extension gives feeder lambs 1 to 1.5 US gallons (3.8 to 5.7 litres), pregnant ewes 1 to 2 gallons (3.8 to 7.6 litres) and lactating ewes 2 to 3 gallons (7.6 to 11.4 litres). It notes that sheep drink more as temperature rises but gives no figures.

Kenya’s Directorate of Veterinary Services advises, in The Standard (18 January 2021), that water should be available at all times. Plan for that: the pump has to fill a tank, not just a trough.

Step 1: add up the herd

Daily need = animals x litres per animal. Take the low and the high end of the range.

Herd Low (50 L per cow) High (100 L per cow)
5 lactating cows 250 litres 500 litres
10 lactating cows 500 litres 1,000 litres
15 lactating cows 750 litres 1,500 litres

Now add the rest of the animals. Example: 10 lactating cows (1,000 litres at the high end) plus 20 adult goats at 2 litres (40 litres) is 1,040 litres a day. Add a margin for hot weeks and for animals you may add. We use 20% in our example, which is our assumption and not a published figure: 1,040 x 1.2 = about 1,250 litres a day.

Step 2: the pump depends on lift, not herd size

Look at the number: 1,250 litres a day is small. Pumped over 6 hours of useful sun (our assumption) that is about 210 litres an hour at the water source. Almost any solar pump can deliver that at a shallow depth. The hard part is the lift. A pump delivers less water as the total lift rises, and the maker’s top flow is not available at the top head.

Two published examples at a stated depth. The Dayliff Sunflo-S 300 stainless steel pump is listed with an indicative flow of about 3 m³ (3,000 litres) a day at 60 m, at KSh 27,300 (taxes included, delivery extra, seen 28 November 2026). That covers the 10-cow, 20-goat example more than twice over at that depth. The Solarpex 4SDS5 800 W kit (KSh 74,000, skywave.co.ke, seen 28 November 2026) states a maximum of 80 m and a maximum of 5 m³ an hour, not both together; the seller does not publish the flow at depth. Check flow at your own total lift in the maker’s pump curve before you buy. Our calculator asks for that lift.

Total lift is the depth from the water level to the surface, plus the height to the tank, plus pipe losses. A borehole drilled 100 m deep can have its water level at 60 m: the 60 m is what counts.

Borehole, dam or river?

  • Borehole: a submersible pump (see borehole pumps). Water is usually cleaner. Ask for a yield test so you do not pump it dry.
  • Dam, river or tank: a surface pump (see surface pumps). Cattle should not wade in the water you draw from. The UC Davis and CIMMYT fact sheet gives a general safe nitrate level of less than 44 ppm and warns that blue-green algae can sicken or kill cattle. Test the water first: see borehole water testing.

Tank, trough and float

  • Tank. Cows drink 30 to 50% of their daily water within an hour of milking (UC Davis and CIMMYT). A trough alone cannot serve that rush from a slow pump. A tank holds the day’s pumping and feeds the trough by gravity.
  • Trough size and flow. The University of Kentucky recommends 3 to 5 inches (about 8 to 13 cm) of drinking space per cow, a trough height of 2 to 3 feet (about 0.6 to 0.9 m), a trough that holds at least 5 US gallons (about 19 litres), a refill rate a little over 2.5 US gallons a minute (about 9.5 litres a minute), and one waterer for every 20 cows. Put it near the feed and milking area.
  • Keep it clean. The same source says to clean automatic waterers and float valves at least once a week. UC Davis and CIMMYT say shade and frequent cleaning reduce algae.
  • Float. A float valve at the trough stops it overflowing. A float switch in the tank tells the pump when to stop, so it does not run against a full tank. Lorentz and Grundfos both describe tank-full controls, and say the pump restarts when the tank is no longer full. We list the Dayliff YDF-3 at KSh 1,280 and the Freevel FS-102W at KSh 550 (see float switches). The Freevel switch is a mains-voltage type (220 to 240 V): ask your installer which float your controller accepts, since Lorentz and Grundfos supply their own level switches.

What to do next

  1. Count animals and decide the daily litres, high end.
  2. Find your total lift.
  3. Use the sizing calculator.
  4. Ask us for a quote. We pass your request to one EPRA-licensed installer and tell you who before sharing your details. If you already have a borehole on diesel, see solar versus diesel.

Pumps that fit

Freevel · Float switch FS-102W, 2 m cable
2 m, copperCableIP65Protection10 mMaximum immersion depth
From KSh 550 Seen 28 Nov 2026 · pureflex.co.ke
Get a confirmed quote
Dayliff · DC 300 W stainless pump, 60 m
300 WPower60 mMax headAbout 3 m³ a day at 60 m (indicative)Flow
From KSh 27,300 Seen 28 Nov 2026 · shop.dayliff.com
Get a confirmed quote
Solarpex · AC/DC hybrid 800 W AC/DC, 80 m head
800 WPower80 mMax head5,000Flow L/h
From KSh 46,000 Seen 28 Nov 2026 · skywave.co.ke
Get a confirmed quote
Solar borehole pumps

Sources

Questions about this

How much water does a dairy cow drink per day in Kenya?
A study of smallholder dairy farms in Makueni County, citing Lardy et al. (2008), gives 30 to 50 litres a day for dry cows and 50 to 100 litres for lactating cows, depending on milk production. The authors add that the upper and lower limits for their region still need to be measured. Heat, feed and milk yield push the figure up.
How much water does a goat or a sheep need?
A KALRO training manual states that an adult goat should take about 2 litres of water a day. North Dakota State University Extension gives pregnant ewes 1 to 2 US gallons (3.8 to 7.6 litres) and lactating ewes 2 to 3 gallons (7.6 to 11.4 litres). Heat raises both.
How big a solar pump do I need for 10 cows?
Ten lactating cows at 50 to 100 litres need 500 to 1,000 litres a day. That is a small volume. The pump size is set mostly by your total lift, not by the herd. A pump rated about 3,000 litres a day at 60 m (the Dayliff Sunflo-S 300's indicative figure) would cover this herd with room to spare. Use the sizing calculator for your own lift.
Do I need a tank?
Yes. A solar pump only works in daylight, and cows drink a large share of their water soon after milking. A tank lets the pump fill during the day while the trough serves the herd at any hour.
Can cows drink straight from a dam or river pumped by solar?
They can, but the water must be fit to drink. Test it. Blue-green algae and nitrate can sicken cattle, and shaded, regularly cleaned troughs reduce algae.

Get a confirmed quote

Free and without obligation. We pass your request to one EPRA-licensed installer in your county, and tell you who before we share your details.

Common:
We need the county to find a licensed installer near you
What the water is for
Pick all that apply.
Please tick the box so we can pass on your request
No payment now. No spam calls.
What happens next
1We read your request and choose one EPRA-licensed installer who works in your county.
2We tell you who it is. Only then do we share your name, phone and county with them.
3The installer checks your borehole and sends a written, itemised quote. You decide.
Your data Used only to answer this request, under Kenya's Data Protection Act 2019. Never sold, never shared with more than one installer. Privacy policy
Size my pumpGet a quote